TECHNICAL DATA AND INSTALLATION INFORMATION
WHAT IS PANFAN?
Panfan is a revolutionary, award winning
product that eliminates toilet odour and the micro-organisms found in that odour
creating a more hygienic, odour-free bathroom.
Panfan comes as a vented or
filtered kit that is activated when the toilet
is in use, creating a vacuum within the bowl
so unfavourable smells never escape!
MODERN SOLUTION TO AN AGE OLD PROBLEM
Pan Fan is a premium product which offers a new solution to an
age old problem. Unlike other extraction methods, Panfan
removes the micro-organisms that cause odour directly from
the bowl so you don't have to breathe them in before they are
extracted from the room.
Pan Fan is available as a retro fit
system and fixed within the bowl eliminating the wasted energy caused from venting your entire powder or bathroom. Saving
you money on power bills and unnecessary air freshener
purchases.
Keeping your bathrooms hygienically clean and fresh, naturally!
EASY TO INSTALL
Panfan can be installed in less than an hour and only requires standard 40mm piping. The system is fit
inside the toilet and vents to the rear of the cistern
just above the waterline.
The odors are then
extracted up the wall via the piping and out to the
soffit to escape to the atmosphere. The fan can be
mounted up to 20m from the cistern in the ceiling, above the roofline, under the floor, on an outside
wall or anywhere it can be accessed for servicing.
Making this an ideal system for new homes,
renovations, and apartment developments.
PANFAN BUILDING ILLUSTRATION
QUICK INSTALLATION GUIDE
Works efficiently up to 20Lm with venting from toilet to outlet/filter.
Pipe Size: 50ø up to 40LM or 40ø up to 20LM
Pipe Bends: Up to 12 bends x 90˚ (if required)
Best time to install: At frame stage (bare walls) during construction, pipework is installed within wall framing (bare walls) with pipe inlet at required height to suit your toilet model. The fan extraction system is fully installed at this time.
Requires: 1 x power point usually connected to the same light switch circuit of the toilet/bathroom.
DO NOT GLUE FAN TO VENT PIPE
Step 1: Determine location of toilet and height of toilet cistern for vent pipe inlet of Panfan.
Step 2: Determine location of external vent to soffit line or roof penetration.
Step 3: Run vent pipe from toilet location to vent location, gluing all pipework.
Step 4: Choose best location along vent pipe installed for Panfan unit. Cut out section of vent pipe to allow for unit to be placed in between. Ensure accessibility for future service.
Step 5: Secure Panfan unit with flexible foam tape (as provided) to vent pipe at each end. DO NOT GLUE unit to end.
Step 6: Plug unit into power outlet, linked to desired switch.
DO NOT GLUE UNIT TO VENT PIPE
Join the team from Bullfrog Constructions onsite to see how they install the Panfan!
SPECIFICATIONS: FAN
Product: | Panfan Vented Inline Fan |
---|---|
Code: | PFV (PFF103 replacement fan only) |
Dimensions: | L 188mm x W 74ø, inlet/outlet 50ø I.D. |
Weight: | 170g (Fan only) |
Power consumption: | 2.04W |
Air flow: | 600L/min free flow |
80-100L/min installed (up to 4x air exchanges/min within toilet bowl) | |
Direction: | Uni directional fan |
Motor: | Input 6v DC Brushed Motor |
Current Load: | 1.0A (Max) |
Run Load: | 0.5A |
Cable: | 150mm L, 1.2mm DC socket |
Fan Material: | ABS |
Ducting Diameter: | 40ø |
Ducting Length: | 20m with 13x 90 ̊ bends |
Fan Location: | Anywhere accessible for service, (generally in ceiling space) indoors/outdoors inline. |
Installation Angle: | The fan should be installed on an angle as to allow any moisture to drain |
Toilet connection: | Ducting Connects to cistern or flush valve outlet side |
Sound Dampening: | Soft connection to duct to reduce noise/vibration |
Approvals: | Meets NCC 2019 and AS 1668.2, and G4 ventilation code |
Meets Ministry of Education toilet reference for design | |
SPECIFICATIONS: POWER SUPPLY
Product: | Panfan Switch Mode Power Adaptor |
---|---|
Code: | PFT301 |
Dimensions: | 69 x 50 x 27mm |
Weight: | 200g |
Input: | AC 100~240V |
50/60Hz 0.3A | |
1.8m twin lead, hardwired | |
Output: | DC 6v 2.0A |
1.8m twin lead, DC 2.1mm plug | |
Installation: | Indoors only |
Approvals: | UL Listed |
CE | |
FCC | |
GS | |
C Tick | |
RoHS | |
FEATURES:
Designed and time tested for over 25 years, it is the most economical, effective and efficient method of toilet odour elimination, directly from the toilet pan. The inline fan is compact using small 40ø pipe up to 20M distance ideal for multi level situations. Being made from durable ABS plastic and safe ultra low voltage, the fan can be mounted outdoors in the weather.
APPLICATIONS:
Perfect for any toilet anywhere, removing toilet odour and micro-organisms found in toilet odour directly from the toilet bowl, preventing them from entering the room. The fan can be mounted in the ceiling, above the roofline, under the floor, on an outside wall or anywhere it can be accessed for servicing.
COMMENTS:
Designed to provide the finest air quality control in the presence of a toilet. Highly effective yet removing a minimal amount of temperature controlled air making it the most energy efficient method of odour control.