Free express shipping

TECHNICAL DATA AND INSTALLATION INFORMATION



WHAT IS PANFAN?


Panfan is a revolutionary, award winning product that eliminates toilet odour and the micro-organisms found in that odour creating a more hygienic, odour-free bathroom.

Panfan comes as a vented or filtered kit that is activated when the toilet is in use, creating a vacuum within the bowl so unfavourable smells never escape!



MODERN SOLUTION
TO AN AGE OLD PROBLEM



Pan Fan is a premium product which offers a new solution to an age old problem. Unlike other extraction methods, Panfan removes the micro-organisms that cause odour directly from the bowl so you don't have to breathe them in before they are extracted from the room.

Pan Fan is available as a retro fit system and fixed within the bowl eliminating the wasted energy caused from venting your entire powder or bathroom. Saving you money on power bills and unnecessary air freshener purchases.

Keeping your bathrooms hygienically clean and fresh, naturally!



EASY 
TO INSTALL



Panfan can be installed in less than an hour and only requires standard 40mm piping. The system is fit inside the toilet and vents to the rear of the cistern just above the waterline.

The odors are then extracted up the wall via the piping and out to the soffit to escape to the atmosphere. The fan can be mounted up to 20m from the cistern in the ceiling, above the roofline, under the floor, on an outside wall or anywhere it can be accessed for servicing.

Making this an ideal system for new homes, renovations, and apartment developments.

PANFAN BUILDING ILLUSTRATION

QUICK INSTALLATION GUIDE

Works efficiently up to 20Lm with venting from toilet to outlet/filter.

Pipe Size: 50ø up to 40LM or 40ø up to 20LM

Pipe Bends: Up to 12 bends x 90˚ (if required)

Best time to install: At frame stage (bare walls) during construction, pipework is installed within wall framing (bare walls) with pipe inlet at required height to suit your toilet model. The fan extraction system is fully installed at this time.

Requires: 1 x power point usually connected to the same light switch circuit of the toilet/bathroom.

DO NOT GLUE FAN TO VENT PIPE

Step 1: Determine location of toilet and height of toilet cistern for vent pipe inlet of Panfan.

Step 2: Determine location of external vent to soffit line or roof penetration.

Step 3: Run vent pipe from toilet location to vent location, gluing all pipework.

Step 4: Choose best location along vent pipe installed for Panfan unit. Cut out section of vent pipe to allow for unit to be placed in between. Ensure accessibility for future service.

Step 5: Secure Panfan unit with flexible foam tape (as provided) to vent pipe at each end. DO NOT GLUE unit to end.

Step 6: Plug unit into power outlet, linked to desired switch.

DO NOT GLUE UNIT TO VENT PIPE

Join the team from Bullfrog Constructions onsite to see how they install the Panfan!

SPECIFICATIONS: FAN

Product:Panfan Vented Inline Fan
Code:PFV (PFF103 replacement fan only)
Dimensions:L 188mm x W 74ø, inlet/outlet 50ø I.D.
Weight:170g (Fan only)
Power consumption:2.04W
Air flow:600L/min free flow
80-100L/min installed (up to 4x air exchanges/min within toilet bowl)
Direction:Uni directional fan
Motor:Input 6v DC Brushed Motor
Current Load:1.0A (Max)
Run Load:0.5A
Cable:150mm L, 1.2mm DC socket
Fan Material:ABS
Ducting Diameter:40ø
Ducting Length:20m with 13x 90 ̊ bends
Fan Location:Anywhere accessible for service, (generally in ceiling space) indoors/outdoors inline.
Installation Angle:The fan should be installed on an angle as to allow any moisture to drain
Toilet connection:Ducting Connects to cistern or flush valve outlet side
Sound Dampening:Soft connection to duct to reduce noise/vibration
Approvals:Meets NCC 2019 and AS 1668.2,
and G4 ventilation code
Meets Ministry of Education toilet reference for design

SPECIFICATIONS: POWER SUPPLY

Product:Panfan Switch Mode Power Adaptor
Code:PFT301
Dimensions:69 x 50 x 27mm
Weight:200g
Input:AC 100~240V
50/60Hz 0.3A
1.8m twin lead, hardwired
Output:DC 6v 2.0A
1.8m twin lead, DC 2.1mm plug
Installation:Indoors only
Approvals:UL Listed
CE
FCC
GS
C Tick
RoHS

FEATURES:

Designed and time tested for over 25 years, it is the most economical, effective and efficient method of toilet odour elimination, directly from the toilet pan. The inline fan is compact using small 40ø pipe up to 20M distance ideal for multi level situations. Being made from durable ABS plastic and safe ultra low voltage, the fan can be mounted outdoors in the weather.

APPLICATIONS:

Perfect for any toilet anywhere, removing toilet odour and micro-organisms found in toilet odour directly from the toilet bowl, preventing them from entering the room. The fan can be mounted in the ceiling, above the roofline, under the floor, on an outside wall or anywhere it can be accessed for servicing.

COMMENTS:

Designed to provide the finest air quality control in the presence of a toilet. Highly effective yet removing a minimal amount of temperature controlled air making it the most energy efficient method of odour control.